Product Overview
Omni R&D's 8-Channel Battery Analyzer is suitable for measuring battery capacity within 50mA-10A, 5V. This system is the best tool for researching new generation energy storage materials and rechargeable batteries. It features:
- 1. Precise programming features: the system software can set the working steps, parameters and working pattern flexibility at each step;
- 2. Each module provides 8 separate programmable channels: built-in power and full control circuits, and each module can work independently. Each channel can be set to work in a different mode. The channels are completely independent;
- 3. Complete controllability: The system software has GOTO, restart and recovery functions, enabling users to change working parameters at any time;
- 4. Windows based software interface, stable performance, easy to operate. The software of the system is simple to operate. Real-time monitoring of Windows and integrated graph/data Windows allows more direct and efficient observation of test processes. During the test, the software will provide timely instructions and warnings, and provide intelligent help in both English and Chinese.
Specifications:
|
|
||||
AC 220V ±10% / 50Hz |
|||||
Active-power input: |
25W |
||||
Resolution ratio: |
AD: 16bit; DA: 16bit |
||||
Input resistance: |
≥1GΩ |
||||
Voltage |
Constant voltage range control: |
25mV~5V |
|||
Minimum discharge voltage: |
-5V |
||||
Precision: |
± 0.05% of FS |
||||
Stability: |
± 0.05% of FS |
||||
Current |
Output range per channel: |
Range 1: 5uA~1mA; Range 2: 1mA~5mA; Range 3: 5mA~10mA |
|||
Precision: |
± 0.05% of FS |
||||
Constant voltage cut-off current: |
Range 1: 2μA; Range 2: 0.01mA; Range 3: 0.02mA |
||||
Stability: |
± 0.05% of FS |
||||
Power |
Single channel maximum output power: |
0.05W |
|||
Stability: |
± 0.1% of FS |
||||
Time |
Current response time (10%FS~90%FS): |
< 500μs |
|||
Step time range: |
≤ (365*24) hour/step |
Time format supports 00: 00: 00: 00 (h, min, s, ms) |
|||
Data record |
Data recording conditions: |
Minimum time interval: 100ms |
|||
Minimum voltage interval: 10mV |
|||||
Minimum current interval: Range 1: 2uA; Range 2: 0.01mA; Range 3: 0.02mA |
|||||
Recording frequency: |
10Hz |
||||
Charge |
Charging mode: |
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging |
|||
Cut-off condition: |
Voltage, current, relative time, capacity,energy, -△V |
||||
Discharge |
Discharge mode: |
Constant current discharge, constant power discharge, constant resistance discharge, constant voltage discharge, constant current and constant voltage discharge |
|||
Cut-off condition: |
Voltage, current, relative time, capacity, energy |
||||
Pulse mode |
Charge: |
Constant current mode, constant power mode |
|||
Discharge: |
Constant current mode, constant power mode |
||||
Minimum pulse width: |
500ms |
||||
Number of pulses: |
A single pulse step supports 32 different pulses |
||||
Charge and discharge continuous switching: |
One pulse step can realize continuous switching from charging to discharging |
||||
Cut-off condition: |
Voltage, relative time |
||||
DCIR test |
Supports the calculation of DCIR by user-defined fetched points |
||||
Cycle: |
Cycle test range: |
1~65535 times |
|||
Number of working steps in a single cycle: |
254 |
||||
Loop nesting: |
With nested loop function, it supports up to 3 levels of nesting |
||||
Protection: |
● Power-down data protection |
||||
● With offline test function |
|||||
● Safety protection conditions can be set, setting parameters include: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, delay time |
|||||
IP protection class: |
Protection class IP20 |
||||
Channel features: |
Constant current source and constant voltage source adopt double closed-loop structure |
||||
Channel control mode: |
Independent control |
||||
Voltage and current detection sampling: |
Four-wire connection |
||||
Noise: |
<45dB |
||||
Data base: |
Centrally manage and test data by using MySQL database |
||||
Upper computer communication method: |
Based on TCP/IP protocol |
||||
Server operating system: |
Windows 7 |
||||
Data output method: |
EXCEL2003, 2010, TXT |
||||
Server disk configuration: |
500GB |
||||
Communication Interface: |
Network port |
||||
Leakage current: |
0.005μA |
||||
The channels number of the whole machine: |
8 |
||||
Equipment working environment requirements: |
|||||
|
|
||||
Range of working temperature: |
0℃~40℃ (In the range of 25±10℃, the measurement accuracy is guarantee; accuracy drift 0.005% of FS /℃) |
||||
Storage temperature range: |
-10℃~50℃ |
||||
Working environment relative humidity range: |
≤70% RH (no condensation) |
||||
Storage environment relative humidity range: |
≤80% RH (no condensation) |
||||
Fixture Specifications and Dimensions: |
|||||
|
|
||||
Fixture Type: |
Upper and lower fixture |
||||
Chassis size per unit (W*D*H): |
1U (19"), 19" x 12.2" x 1.8" |