Product Overview

Omni R&D's 8-Channel Battery Analyzer is suitable for measuring battery capacity within 50mA-10A, 5V. This system is the best tool for researching new generation energy storage materials and rechargeable batteries.  It features:

  • 1. Precise programming features: the system software can set the working steps, parameters and working pattern flexibility at each step;
  • 2. Each module provides 8 separate programmable channels: built-in power and full control circuits, and each module can work independently. Each channel can be set to work in a different mode. The channels are completely independent;
  • 3. Complete controllability: The system software has GOTO, restart and recovery functions, enabling users to change working parameters at any time;
  • 4. Windows based software interface, stable performance, easy to operate. The software of the system is simple to operate. Real-time monitoring of Windows and integrated graph/data Windows allows more direct and efficient observation of test processes. During the test, the software will provide timely instructions and warnings, and provide intelligent help in both English and Chinese.

Specifications:

  • Index item
  • Index parameter

Input power:

AC 220V ±10% / 50Hz

Active-power input:

25W

Resolution ratio:

AD: 16bit; DA: 16bit

Input resistance:

1GΩ

Voltage

Constant voltage range control:

25mV~5V

Minimum discharge voltage:

-5V

Precision:

± 0.05% of FS

Stability:

± 0.05% of FS

Current

Output range per channel:

Range 1: 5uA~1mA; Range 2: 1mA~5mA; Range 3: 5mA~10mA

Precision:

± 0.05% of FS

Constant voltage cut-off current:

Range 1: 2μA; Range 2: 0.01mA; Range 3: 0.02mA

Stability:

± 0.05% of FS

Power

Single channel maximum output power:

0.05W

Stability:

± 0.1% of FS

Time

Current response time (10%FS~90%FS):

< 500μs

Step time range:

(365*24) hour/step

Time format supports 00: 00: 00: 00 (h, min, s, ms)

Data record

Data recording conditions:

Minimum time interval: 100ms

Minimum voltage interval: 10mV

Minimum current interval: Range 1: 2uA; Range 2: 0.01mA; Range 3: 0.02mA

Recording frequency:

10Hz

Charge

Charging mode:

Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging

Cut-off condition:

Voltage, current, relative time, capacity,energy, -△V

Discharge

Discharge mode:

Constant current discharge, constant power discharge, constant resistance discharge, constant voltage discharge, constant current and constant voltage discharge

Cut-off condition:

Voltage, current, relative time, capacity, energy

Pulse mode

Charge:

Constant current mode, constant power mode

Discharge:

Constant current mode, constant power mode

Minimum pulse width:

500ms

Number of pulses:

A single pulse step supports 32 different pulses

Charge and discharge continuous switching:

One pulse step can realize continuous switching from charging to discharging

Cut-off condition:

Voltage, relative time

DCIR test

Supports the calculation of DCIR by user-defined fetched points

Cycle:

Cycle test range:

1~65535 times

Number of working steps in a single cycle:

254

Loop nesting:

With nested loop function, it supports up to 3 levels of nesting

Protection:

Power-down data protection

With offline test function

Safety protection conditions can be set, setting parameters include: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, delay time

IP protection class:

Protection class IP20

Channel features:

Constant current source and constant voltage source adopt double closed-loop structure

Channel control mode:

Independent control

Voltage and current detection sampling:

Four-wire connection

Noise:

<45dB

Data base:

Centrally manage and test data by using MySQL database

Upper computer communication method:

Based on TCP/IP protocol

Server operating system:

Windows 7

Data output method:

EXCEL2003, 2010, TXT

Server disk configuration:

500GB

Communication Interface:

Network port

Leakage current:

0.005μA

The channels number of the whole machine:

8

Equipment working environment requirements:

  • Index item
  • Index parameter

Range of working temperature:

0℃~40℃ (In the range of 25±10℃, the measurement accuracy is guarantee; accuracy drift 0.005% of FS /℃)

Storage temperature range:

-10℃~50℃

Working environment relative humidity range:

70% RH (no condensation)

Storage environment relative humidity range:

80% RH (no condensation)

Fixture Specifications and Dimensions:

  • Index item:
  • Index parameter:

Fixture Type:

Upper and lower fixture

Chassis size per unit (W*D*H):

1U (19"), 19" x 12.2" x 1.8"

 